A study of the engineering and economic effects of heat exchangers in conventional maple syrup evaporators indicated that: (1) Efficiency was increased by 15 to 17 percent with heat exchangers; (2) Syrup produced in evaporators with heat exchangers was similar to syrup produced in conventiona lsystems in flavor and in chemical and physical composition; and (3) Heat exchangers reduce per unit production costs, and can yield greater production and higher profits.